TASCO MANIFOLD

HARGA TASCO MANIFOLD

Inspeksi Pra Pengiriman Pengiriman Manifold

Setelah jalur perakitan, kami memeriksa semua manifold gauge.
Hanya produk yang lulus inspeksi yang dikirimkan ke pelanggan.
Misi kami adalah melanjutkan upaya kami untuk memasok produk-produk berkualitas tinggi.

Proof of TASCO Quality

Pengukur Tekanan Presisi Tinggi & Pengukur Kompon

Alat pengukur tekanan & pengukur tekanan presisi tinggi TASCO melewati inspeksi berat.
Skala Gauge TASCO 80mm sesuai dengan yang ketat
standar, JIS class-1.6.
Sertifikat Tes Tekanan menunjukkan nomor seri lot &
orang yang bertanggung jawab memotong.
Kami memiliki keyakinan dalam pengukur tekanan presisi tinggi.

JAPAN Quality

Selang Pengisian Berkualitas Tinggi

Kami memasang selang pengisian satu per satu
dengan fitting metal desain eksklusif.
Semua selang diukir dengan tahun
produksi.
Kami memiliki kepercayaan diri pada selang berkualitas tinggi.

GAUGE MANIFOLD

The pressure of the new refrigerant for the room A/C system R410A/R32 is 1.6 times higher in pressure than the conventional refrigerant R22. Therefore, the standard diameter of the system service port has been changed from 7/16 UNF-20 (1/4 flare) to 1/2 UNF-20 (5/16 flare) in order to prevent system damage and personal injury due to mischarging. In addition, most of the types of refrigerant oil (synthetic oil) which are used for the HFC new refrigerant system are different substantially from the types of refrigerant oil (mineral oil) which were used for the conventional system. If the two different types of oil are mixed, impurities will be composed to cause system damage. If material for the conventional refrigerants is used as material of HFC refrigerant seals, cracks and melting will occur to cause gas leakage. It is necessary to use HFC-proof HNBR or material coated with a special type of nylon. R410A refrigerant is a blend of R125 and R32. Basically, it should be charged in a liquid phase in order to avoid composition change.

R410A/R32 BALL VALVE MANIFOLD

BALL VALVE ASSURES AND ENABLES A EASY AND ACCURATE JOB. CAN ALSO CHECK GAS BY LOOKING INTO THE SIGHT GLASS.